Design and application of flotation systems for the treatment of reinjected water in a Colombian petroleum field

  • Jorge Enrique Forero Ecopetrol S.A. – Instituto Colombiano del Petróleo, A.A. 4185 Bucaramanga, Santander, Colombia
  • Olga Patricia Ortiz Universidad Industrial de Santander, Bucaramanga, Santander, Colombia
  • José Javier Duque Ecopetrol S.A. – Instituto Colombiano del Petróleo, A.A. 4185 Bucaramanga, Santander, Colombia
Palabras clave: separation, oil, water, flotation, emulsion, waste water, produced water, oil-fields, produced water re-injection, induced gas flotation

Resumen

En este articulo de presenta la aplicación de un nuevo proceso de flotación, desarrollado por Ecopetrol S.A., para el tratamiento de agua de producción o residual para inyección en campos de producción de petróleo. Últimamente el costo de tratamiento de estas aguas se ha incrementado debido a condiciones de calidad mas estrictas, especialmente en el contenido de sólidos en suspención y/o hidrocarburos en emulsión, los cuales deben ser tratados hasta niveles muy bajos (menores a 5 ppm). Además también se han incrementado considerablemente el volumen de agua a tratar, en algunos casos, hasta en 100 veces. Considerando los resultados obtenidos de la aplicación industrial de este proceso de flotación, se observó que es una alternativa muy valiosa, con ventajas sobre los procesos convencionales, especialmente en términos de eficiencia, consumo de energía, costos y de proceso.

Referencias bibliográficas

Abou-Sayed, A (2005). Produced water management strategy- saving the asset from drowning in produced water. Business Briefing: Exploration & Production: The oil & Gas Review,106-110.

Al-Shamran, A.A. (2001). Separation of oil from water by dissolved air flotation. Department of Chemical Engineering, Environmental Technology Centre.The University of Manchester, Institute of Science and Technology UMIST, Manchester, UK, Dec.13.

Forero, J.E., Diaz, J., & Blandón, V.R. (1999). Diseño de un nuevo sistema de flotación para tratamiento de aguas industriales. CTYF- Ciencia Tecnología y Futuro, 1 (5): 67-75.

Lee, J.E. (2003). A Study of the Bubble Properties in the Column Flotation System. HydroLab Institute, Sum-Jin EST Company, School of Mechanical Engineering, Pusan National University, San 30, Changjeon-Dong, Keumjeong-Ku, Busan 609-735, Korea; April 17. https://doi.org/10.1007/BF02697303

Lee, J.E. (2002). Effect of Microbubbles and Particle Size on the Particle Collection in the Column Flotation. HydroLab Institute, Sum-Jin EST Company, Songjeong-Dong, Gangseo-Gu, Busan 618-270, Korea. Department of Mechanical Engineering, Pusan National University, Pusan, Korea.

https://doi.org/10.1007/BF02699321

Matijevi, E. (1981). Interactions in mixed colloidal systems (heterocoagulation, adhesion, microflotation). Pure & Appl.Chem., 153: 2167-2179. Institute of Colloid and Surface Science and Department of Chemistry, Clarkson College of Technology, Potsdam, New York, USA. https://doi.org/10.1351/pac198153112167

Plebon, M.J. (2004a). Advances in Total Oil Remediation and Recovery system for Produced Water. EARTH -Canada- Corporation, Montreal, Quebec, Canada.

Plebon, M.J. (2004b). Advances in produced water oiling utilizing a recently developed technology which removes recovers dispersed oil in produced water 2 microns and larger. EARTH -Canada- Corporation, Montreal, Quebec, Canada.

Pyke, B. (2004). Bubble-Particle Capture in Turbulent Flotation Systems. (B. App.Sci.(Hons), B. Bus), Ian Wark Research Institute, University of South Australia, Adelaide, Australia.

Sander, E., De Rijk., Jaap, H.J.M., Van D.G.,y Jan, G.D. B. (1994). Bubble size in flotation thickening. Delft University of Technology, Faculty of Civil Engineering and Water Managemente, Delf, The Netherlands, 465-473. https://doi.org/10.1016/0043-1354(94)90284-4

Strickland, T. Jr. (1980). Laboratory results of cleaning produced water by gas flotation. SPE Journal 7805, Shell Development Co., 175-190. https://doi.org/10.2118/7805-PA

Cómo citar
Forero, J. E., Ortiz, O. P., & Duque, J. J. (2007). Design and application of flotation systems for the treatment of reinjected water in a Colombian petroleum field. CT&F - Ciencia, Tecnología Y Futuro, 3(3), 147–158. https://doi.org/10.29047/01225383.483

Descargas

Los datos de descargas todavía no están disponibles.
Publicado
2007-12-31
Sección
Artículos de investigación científica y tecnológica

Métricas

QR Code