Analysis of effluent from caustic treatment plants: Improvement of accuracy in the simultaneous potentiometric determination of sulfide and mercaptide ions

  • Marcio V. Reboucas Braskem S.A., Unidade de Insumos Basicos, Laboratorio, Rua Eteno 1561, Complexo Petroquimico de Camacari, Camacari-Bahia, Brazil, 42810-000
  • Ana Rosa C. G. Massa Braskem S.A., Unidade de Insumos Basicos, Laboratorio, Rua Eteno 1561, Complexo Petroquimico de Camacari, Camacari-Bahia, Brazil, 42810-000
  • Marcos Vinicio Assis Braskem S.A., Unidade de Insumos Basicos, Laboratorio, Rua Eteno 1561, Complexo Petroquimico de Camacari, Camacari-Bahia, Brazil, 42810-000
Palabras clave: sulfide, thiol, potentiometric titration, interference, sodium hydroxide

Resumen

La titulación potenciométrica utilizando nitrato de plata para determinación de iones de sulfuro y mercaptido como lo define la UOP Método 209, ha sido ampliamente utilizada para establecer el control de calidad de la Unidad de Neutralización Cáustica para las industrias del petróleo. Sin embargo, se ha establecido que este procedimiento no arroja resultados precisos para muestras tomadas de unidades basadas en Oxidación por Aire Humedecido (WAO). Por consiguiente, se investigaron las fuentes de error tales como especies concomitantes, interferencia entre análitos y solvente de titulación y se propusieron ajustes del método. Deben utilizarse medios acuosos para preparar la solución de titulación, en lugar del solvente alcohólico recomendado, el cual demostró estar relacionado con las recuperaciones de análitos bastante bajas en las muestras de la unidad WAO. El método modificado puede aplicarse con éxito a muestras que tengan distintas composiciones químicas, lo cual es la principal ventaja sobre el procedimiento de referencia. Se lograron límites de detección y desviaciones estándar relativas de 0,5 mg.L-1 y 5,2% para sulfuros y 0,6 mg.L-1 y 5,5% para mercaptidos.

Referencias bibliográficas

Carlos, T. M. S., & Maugans C. B. (2002). Manage refinery spent caustic efficiently. Hydrocarbon Processing, 81 (2), 89-92.

Horwitz, W. (1982). Evaluation of analytical methods used for regulation of food and drugs. Anal. Chem., 54: 67A-76A. https://doi.org/10.1021/ac00238a765

Karchmer, J.H. (1957). Potentiometric determination of mercaptans in presence of elemental sulfur, Anal. Chem., 29: 425. https://doi.org/10.1021/ac60123a028

Karchmer, J.H. (1958). Determining sulfur compounds in petroleum naphtha - The humble scheme. Anal. Chem., 30: 80. https://doi.org/10.1021/ac60133a023

Luck, F. (1999). Wet air oxidation: past, present and future. Catalysis Today, 53: 81-91. https://doi.org/10.1016/S0920-5861(99)00112-1

Sheu, S., & Weng, H. (2001). Treatment of olefin plant spent caustic by combination of neutralization and fenton reaction. Wat. Res., 35: 2017. https://doi.org/10.1016/S0043-1354(00)00466-8

Tamele, M.W., Ryland, L.B., & McCoy, R.N. (1960). Simultaneous determination of hydrogen sulfide and mercaptans by potentiometric titration. Anal. Chem., 32: 1007. https://doi.org/10.1021/ac60164a034

UOP Method 209-00. Alkalinity, sulfide and mercaptide analyses of used refinery caustic solutions.

Cómo citar
Reboucas, M. V., G. Massa, A. R. C., & Vinicio Assis, M. . (2006). Analysis of effluent from caustic treatment plants: Improvement of accuracy in the simultaneous potentiometric determination of sulfide and mercaptide ions. CT&F - Ciencia, Tecnología Y Futuro, 3(2), 163–170. https://doi.org/10.29047/01225383.499