Abstract

In this study, ozone efficiency on the treatment of wastewater contaminated with high amounts of spent caustic (byproduct from hydrocarbons sweetening processes), is evaluated. The type of feedstock, pH, gas/liquid ratio and influence of catalyst use, are analyzed, in addition to the contact system used for the experiments. As a main conclusion, the feasibility of ozone in the treatment of industrial residues was established, especially in wastewater with high phenol contents.

References

Berné, F. and Cordonnier, I, 1995. "Industrial Water Treatment". Institut Francais du Pétrole Publications, Paris.

Blaich, L., 1999. "Developmenl Of Ozone Technology And Application". Proceedings Of The 14Th Ozone World Congress. Dearbon, MI, Aug. 22-28.

Forero, I., Díaz, I. y Blandón, V, 1999. "Diseño de un nuevo sistema de flotación para el tratamiento de aguas industriales". CT&F-Ciencia, Tecnología y Futuro, 1(5): 67-75.

Forero, I., 2000. "Manejo integral de sodas y disposición de sodas gastadas". Documento interno Ecopeírol, CIT-ICP colección resíringida.

Gurol, M. D. and Singer, P. C, 1982. "Kinetics of Ozone Decomposition". A Dynamic Approach. Envir. Sci. Technol, 21 (895), 16 (7): 377-383. https://doi.org/10.1021/es00101a003

Gurol, M. D. and Vatista, R., 1987. "Oxidation of phenol by Ozone and Ozone + UV Radiation: A Comparative Study". Wat. Res., 21 (895). https://doi.org/10.1016/S0043-1354(87)80006-4

Hoigné, J. and Bader, H., 1977. "Ozonation of Water: Selectivity and Rate of Oxidation of Solutes". Proceedings Of The 3th Ozone World Congress, Paris, France.

Hoigné, J. and Bader, H., 1983. "Rate Constants of Reaction of Ozone with Organic and Inorganic Compounds in Water". Water Research, 17:173-183. https://doi.org/10.1016/0043-1354(83)90098-2

Langlais, B. and Reckhow D. A., 1991. "Ozone in Water Treatment Application and Engineering", Lewis Publishers Inc., Chelsea.

Longemann, F. and Annee, H., 1997. "Water with Fixed Bed Catalytic Ozonation Process". Wat. Sci. Tech., 35, (4): 353-360. https://doi.org/10.2166/wst.1997.0151

Masten, S. J. and Davies, S. H. R., 1994. "The Use of Ozonation to Degrade Organic Contaminants in Wastewaters". Envir. Sci. Tech., 28 (4): 180A-186A. https://doi.org/10.1021/es00053a718

Rebhun, M. and Galil, N., 1994. "Technological Strategies for Protecting and Improving the Biological Treatment of Wastewater from a Petrochemical Complex", Wat. Sci. Tech., 29:133-141. https://doi.org/10.2166/wst.1994.0461

Staehelin, J. and Hoigne, J., 1982. "Decomposition of ozone in water: rate of initiation by hydroxide ions and hydrogen peroxide". Envir. Sci. Tech., 16 (10): 676 - 681. https://doi.org/10.1021/es00104a009

Trapido, M, 1999. "The Application Of Ozonation and Advanced Oxidation Processes for Degradation and Detoxication of Phenolic Compounds". Proceedings Of The 14th Ozone World Congress, Dearborne, Michigan.

How to Cite
FORERO, J. E., DUQUE, J. J. ., RIOS, . F., & DÍAZ, J. (2001). Ozone for phenol treatment in industrial wastewater. CT&F - Ciencia, Tecnología Y Futuro, 2(2), 17–26. https://doi.org/10.29047/01225383.547

Downloads

Download data is not yet available.
Published
2001-12-31
Section
Scientific and Technological Research Articles

Altmetric

Crossref Cited-by logo
QR Code